Design of double channel section in STAAD needs improvement

At present design of double channel in STAAD as per IS800 LSD is having certain work flow. It assumes higher MI as a major axis even if it can be about minor axis Y which is not correct. STAAD should consider section orientation as provided by use...
Guest over 1 year ago in  1 Already exists

Design of double I section as column is required.

In most of the industrial sheds, double I section spaced apart is used as crane column and single I section is used to support the roof above. In present STAADpro ver 24 facility to design double I section as per IS800 LSD is not available . This ...
Guest over 1 year ago in  1 Needs review

Turkish Seismic Code

Provide the Turkish Seismic Code (TBSC-2018) which was updated in 2018 for static seismic and response spectrum loading. Code attached.
Guest over 3 years ago in  3 Future consideration

Section properties edit to remember previous selection

When you open a Section from the Properties panel by double-click, you are prompted to the same Table, including section type as the one you double-clicked. That is OK. But the table is just opened regardless of what section size or configuration ...
Saul Cuen over 3 years ago in  1 Already exists

Pipelink Improvement

The pipelink transfer of loads from AutoPIPE to STAAD is currently very limited for guide-type supports and other multi-direction supports. A guide support will have vertical loads as well as lateral loads. Depending on the direction of the latera...
Michael Wood over 3 years ago in  5 Needs review

Warning based on superceded (old) code appears in Seismic analysis using IS 1893 pt 1.

STAAD Pro CONNECT Edition shows a warning based on IS 1893 part 1:2002, when the latest code available currently under use is IS 1893 part 1:2016. Kindly clarify why should warnings based on old codes appear when the user has specifically selected...
ABHISHEK Ramesh over 1 year ago in  0 Needs review

OpenSTAAD function to capture a view and save

Users have requested to have an OpenSTAAD function to capture a view in STAAD.Pro and save it to a file which would help them automate report creation with images.
Aswathi A over 3 years ago in  1 Future consideration

Tapered Sections naming in STAAD.Pro

I think it is a good idea to allow users to name their Tapered sections as with the prismatic sections or sections created by user table. Because many times user creates many tapered sections in his model, andt when it comes to modifying one of th...
Guest almost 7 years ago in  2 Future consideration

Steel Check Code for all code, please make it uniform format

ANL file for steel code has changed format can you revert back again or atleast put to option on Track command to retain original format.
Guest over 1 year ago in  0 Needs review

Add steel fireproofing specification to STAAD.pro Physical Modeler.

Currently, the only way to use STAAD.pro fireproofing specification is thru the Analytical Modeler. If you have a physical model, you have to break the connection and then edit the Input file to remove the "DO NOT EDIT" restrictions so that you ca...
Guest over 1 year ago in  0 Needs review