All ideas

FLAT SLAB, RIBBED SLAB AND WAFFLE SLAB

May you please include the design of waffle slab, ribbed slab and flat slab in rcdc
Joseph Lucas Magare almost 6 years ago in  1 Future consideration

Automatic Effective length calculation for the Indian and Australian steel design codes

This feature is already available for the AISC and Euro Steel design codes. Please implement the same for the Indian and Australian steel design codes.
Madhan Elumalai over 1 year ago in  0 Needs review

OpenSTAAD Function to Redefine Member/Plate Incidence

There will be many occasions where a user wants to redefine the incidence of one or more members or plates. It would be helpful if there is an OpenSTAAD function to carry out this task as this saves a lot of effort and time. I understand that ther...
Srinivasa Rao Masanam almost 3 years ago in  3 Already exists

Connections design using angle & channel connections should be added in ram connection

Connections design using angle & channel connections should be added in ram connection
Saif Altaf Hussain Tickley over 1 year ago in  0 Needs review

when standard sections are used instead of legacy analysis cant be imported to RCDC

In the new staad edition standard sections were added in addition to legacy.but when standard scetions were used, the analysis file cant be imported to RCDC.please solve this as there are new standard sections added which are not available in legacy.
Guest over 1 year ago in  0 Needs review

ASCE 7-22 Code For Response Spectrum Loading

Request on behalf of Teppei Oowaki with JGC Corporation. User asks that the ASCE 7-22 code be implemented for response spectrum loading.
Phil Riegel over 1 year ago in  0 Future consideration

Capacity Design as per NZS3404

Currently STAAD is performing only geometrical check of the members in accordance with Chapter 12 of NZS 3404. However, no design is performed based on the capacity design principles provided in this Chapter. As industries in New Zealand is increa...
Guest over 1 year ago in  0 Needs review

Verification of User-Defined Steel Reinforcement

Good morning. It would be helpful if future versions included the option for the user to define the reinforcement layout, allowing STAAD Foundation Advanced to verify it — both for pedestals and foundations
Guest over 1 year ago in  0 Needs review

CANADA/NRC seismic code 2023

Presently Staad pro is using CANADA/NRC seismic code 2010, but available code is 20213 , kindly update your Staad soft ware accordingly, to perform our Canadian client asap
Guest over 1 year ago in  0 Needs review

Untie the Section Name in the Properties window from the Base Unit settings

The proposed enhacement would allow the units that are being used in the model to appear correctly and complete in the Section Name window, and also in the reports because, for example, being tied as they are now only allows units to be presented ...
Alberto Prieto Noyola over 1 year ago in  0 Needs review