Full integration with AutoPIPE and STAAD

Pipelink is quite rudimentary. It does not provide the ability to assign guide supports to different nodes. For example, horizontal loads need to be applied to Vertical Members, while vertical loads need to be applied to Horizontal Members. The sa...
Sujaan Ahamed Fareed about 2 years ago in  3 Needs review

Please provide report data in txt format for export in versions after 2023, as we need to maintain consistency with previous versions

Please provide report data in txt format for export in versions after 2023, as we need to maintain consistency with previous versions
Guest about 2 years ago in  1 Needs review

Additional Selection Tools

It would be much helpful if additional tools to select entities like Nodes, Beams etc., in the polar coordinate system i.e., specifying the start and end radius (or diameter) and start and end angles. This helps a lot if we need to select the enti...
Srinivasa Rao Masanam about 2 years ago in  1 Will not implement

AI Assistant in Staad.Pro

The possibility of adding an 'AI Assistant' type tool, for example: "Alexa" or "Siri", which with natural language is able to interpret what the user asks for and execute the orders requested.
Guest about 2 years ago in  1 Will not implement

Scale factor for displacement quantities in response spectrum analysis as per IS 1893:2016 amendment no-2 (additional clause 7.7.3.2) regarding

It is understood that while performing response spectrum analysis, the scale factor (V_b/V_B ) Where,V_b=Equivalent static base shear,〖 V〗_B Response spectrum base shear), is automatically accounted for calculation of design base shear. But,this s...
Parameswaran G about 2 years ago in  0 Needs review

Ciudad de Mexico NTC code 2023

To update/include the specifications for mexican regulation for Ciudad de Mexico to the latest version 2023 which include loads specifications, seismic, wind, or at least the steel and concrete.
Saul Cuen about 2 years ago in  1 Future consideration

Canadian steel design routine should recognize FY/FU from material definition.

Use the material definition used for the analysis to determine the default steel strength/grade for steel design when using the Canadian steel design codes CSA S16, using a similar logic to that used when determining the steel strength/grade for d...
Phil Riegel about 2 years ago in  1 Future consideration

Tables with inbuild worksheet like sorting facilities

When sorting information in a worksheet, you can rearrange the data to find values quickly. You can sort a range or table of data on one or more columns of data. you can sort load cases in display tables for both input and output data directly in ...
Guest over 2 years ago in  1 Already exists

Postprocessing member design/revision without re-run analysis

Currently after run analysis we can see the status of design in postprocessing. If fail design appear, now we have to edit and rerun all model and check if edition is good or not. When only 5~10% of members fails, and in large models, this is very...
Saul Cuen over 4 years ago in  1 Future consideration

implementation of design of double ISMB Box section profile while designing in code IS-800-2007-LSD.

When we are assigning ISMB 400*450 Box Section (Double Profile) while designing in Code IS-800-2007-LSD , Members are not able to design & Error coming. Kindly resolve the issue.
Guest over 4 years ago in  1 Future consideration