Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

The name of the load can be modified

When there are many types of load definitions, it is difficult to distinguish which one each load is. If you can customize the name, it will be easier to distinguish and verify
Guest over 2 years ago in  5 Already exists

Add fire calculation in staad.pro

according to GB 51249-2017, steel structure needs to do the fire calculation and corresponding design. There are more and more security reviews about fire calculation, therefore it's necessary to add these content in staad.pro.
Guest over 2 years ago in  1 Future consideration

IMPLEMENTATION OF 4 PLATE WITH DIFFERENT THICKNESS

There is no option for 4 plates or tube beams with different thickness. Also, it could be fantastic an option with tapered tube section with different flange width or thickness
Guest over 1 year ago in  1 Already exists

Use Center of the Structure as rotation Center

The Orientation Settings window provides the option "Use the center of the structure as the rotation center". However, when i perform the "Display Whole Structure" function, the rotation center is reset to 0,0,0. This happens when the Orientation ...
Guest over 2 years ago in  0 Needs review

Shrink diagram enhancement

It would be helpful if the Shrink command under Structure Diagram would only shrink the members with released ends. This would make the diagrams look more like a design drawing and would make it easier to check that you have released the right mem...
Nick Wilde over 1 year ago in  1 Future consideration

Calculation of Stability index Q as per annex E of IS456

To determine whether a column is a no sway or a sway column, stability index Q may be computed as given in annex-e of IS456. It's a very time consuming and cumbersome calculation while we are freezing the column sizes. if Q is directly calculated ...
Guest over 2 years ago in  4 Future consideration

Include Aluminum Design Results in Report

Philip Bamu with PCB International, LLC requests that the STAAD.pro Report functionality be updated to include aluminum design results.
Phil Riegel over 1 year ago in  1 Future consideration

Reuse the water tank module to form a retaining wall module in SPPM

Are there any plans to use the Water Tank module in Structure Wizard in the Physical Modeler to create a retaining wall module? It seems like this could be developed easily from the water tank module.
Richard Tully almost 4 years ago in  1 Needs review

implement front to front angle configuration in STAAD

In India many Columns are made with 4 leg of angle with lacing of rod or angle(built-up) STAAD have option of design back to back but it is not have front to front angle configuration
Rahul Brijpuriya over 2 years ago in  2 Will not implement

ADD the slenderness ratio to the normalized ratio

If the slenderness ratio meets the requirements, but its normalized ratio is not shown in the utilization table, can the slenderness ratio be added to the utilization table, which will help the designer to understand the condition of the member.
Guest over 2 years ago in  1 Needs review