All ideas

Showing 319 of 319

Include the moving load possibility in physical model

No description provided
Guest about 2 months ago in  3 Needs review

Enable view of in-plane bending moment for each wall plate in masonry & concrete shear walls.

Currently I need to cut a line or plane at the base of a masonry shear wall in order to determine the in-plane bending moment. However, that effort produces the total moment for the entire cut. It would be more convenient if I could just click on ...
Guest about 2 months ago in  2 Needs review

implement Indian Aluminum design code in STAAD Pro

implement Indian Aluminum design code in STAAD Pro
Guest about 2 months ago in  1 Needs review

addition of new beams in existing group definition

currently if anyone need to add the beams in group definition, all the beams including existing added need to be selected. if new beams can be added without selecting existing beams, it will be easier
Guest 2 months ago in  1 Future consideration

Highlight the beam when UDL selected

In load data page when you select any specific UDL or point load, then the UDL or point load associated beam and node shall be auto selected or highlighted. this will help to identify if load applied is at right location or not
Guest 2 months ago in  1 Will not implement

Multiple design parameters results in post processing window for Indian code IS 800-2007 is requested.

This will reduce the tedious process of turning on and off each design parameter from editor file and then running the full input file again multiple times. If this can be implemented for AISC-360 then it shall be implemented for other codes also.
Guest 2 months ago in  1 Future consideration

Company Logo needs to be changed for every project, that is a tedious practice.

While generating Report, Company Logo needs to be changed for every project, that is a tedious practice. The changes should be permanent and for company.
Guest 2 months ago in  1 Already exists

OpenSTAAD Function to Renumber Node

We request to at the OpenSTAAD function to renumber Nodes just like we do with beams.
Kanagarasu Kandasamy 2 months ago in  1 Future consideration

OpenSTAAD function to extract the Beam Forces summary table for the selected beams

Hi, Typically, to get end forces to design the connection for a certain beam size, a group is created and the bounding beam forces for the group are extracted using the "Beam Results - Beam Forces - Summary table" using the "Results Setup - Range ...
Tom Pallister 2 months ago in  1 Future consideration

Add load to the node/beam/element group using OpenSTAAD

Hi, I have an OpenSTAAD program that generates groups and that applies loads to the elements/beams/nodes in those groups. However I'd like to apply the load to the group directly using openSTAAD as you can in the STAAD Command File? What I want to...
Tom Pallister 2 months ago in  1 Future consideration