Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Make Staad Multi Processor (Multi-Threaded)

This would cut down the analysis time required by STAAD significantly. If it is too much work to change the solver code to benefit from multi-threads, can at least each basic load or each load combination be run at a different thread? There's no r...
Rafael Salgado almost 4 years ago in  1 Future consideration

A few formal comments

The "Individual Beam Label" command is very useful, I would just redesign it. Now it's like this: if I want, for example, a unit check of only some members, I have to first display all of them and then click out the ones I don't want, so that I ca...
Guest 7 months ago in  1 Needs review

Indicate of number of LOAD LIST ENVELOPE

As shown in the attached screenshot, the STAAD program does not display the load list envelope numbers, which causes inconvenience for users. Please improve this feature.
정모 고 over 1 year ago in  3 Future consideration

[CS0679673] Stretch Beam command doesn't work consistently

The routine for stretching members is NOT designed to support members that overlap existing members as mentioned by development team. But this logic is not consistent across all locations. The stretch beam routine sometimes fails to detect the ove...
Suvadeep Acharjee 4 months ago in  5 Needs review

BUG REPORT REPRESNTAION

Previously, STAAD provided detailed bug reports through the following link: https://bentleysystems.service-now.com/community?id=kb_article_view&sys_kb_id=453e131c47b7ea507798d4fe536d43e8.However, currently, STAAD only shows a one-line descript...
RAHUL BRIJPUIYA 11 months ago in  2 Needs review

Calculation of Ay/Az shear areas and TD/TB values for the General sections

Previously, STAAD.Pro was capable of calculating the Ay/Az shear areas when exporting non-standard shapes from the Section Wizard or when defining a General UPT section using profile points. However, in the latest versions of STAAD.Pro, the softwa...
Modestas Turulis 11 months ago in  1 Needs review

AutoDrafter - Allow Turn On/Off Layers

Some layers in autodrafter clog up the view of the drawing (e.g., member centerlines). It would be great if layers can be turned on/off within AutoDrafter Drawing Style Manager.
Michael Duncanson over 1 year ago in  0 Needs review

Story Shear for Wind and Seismic Loads:

At present, only storey drift & displacements are reported. There is a need to include storey shear values for both the X and Z directions to support comprehensive analysis.- There is an enhancement request already in place for this. For Euroc...
Rashmi Ramachandra about 1 year ago in  2 Needs review

Add WWF shapes to standard library

The old legacy section properties databases had WWF shapes (at least for Canada) but they weren't copied over to the new standard section properties database. It would be better if they were.
Noel Zimmer 4 months ago in  0 Needs review

Beam local axis symbol, scaling

After being introduced to StaadPRO, the one fundamental thing that I can't believe is not implemented is scaling of local beam axis symbols. It's at times almost impossible to find out the local axis of the beams in the graphic area, and this is v...
Oyvind Fredriksen 11 months ago in  2 Needs review