Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

Status Future consideration
Created by Shubhankar Chatterjee
Created on Jul 6, 2023

In wind load generator, please incorporate wind load in other directions such as X & Z. Also, wind load on roof truss & corners needs to be incorporated.

There is no way to add wind load in other direction in case of unclad building. For example : - staad taking load case only in one direction i.e. +X, whenever I try to add another case in z direction, previous case gets deleted automatically.

So, it would be great if we can add wind load from all 4 directions.

  • PRASHANT LELE
    Reply
    |
    Dec 20, 2023

    Further, the wind load generator should generate wind load on the roof too, as mentioned above, in addition to generating wind loads in both directions namely X & Z in the same model. This is a essential development required as it will fulfill the purpose of wind load generator.

    Thank you.

  • Admin
    Carlos Aguera
    Reply
    |
    Jul 7, 2023

    Are you referring to a limitation in the Physical Workflow? This is certainly possible in the STAAD data file which can have multiple definitions applied simultaneously in a single load case, e.g.

    LOAD 1 LOADTYPE Wind TITLE WIND FROM LEFT (+X) LOAD CASE

    WIND LOAD X 0.8 TYPE 1

    WIND LOAD -Z -0.7 TYPE 1

    WIND LOAD -X 0.5 TYPE 1

    WIND LOAD -Z 0.7 TYPE 1

    ...

    In the Physical modeller, yes a load case is currently limited to have a single definition applied in a single direction. To account for the wind on each face, create four load cases, one for each face and then combine with the appropriate factor, e.g.

  • Admin
    Carlos Aguera
    Reply
    |
    Jul 6, 2023

    Thank you for posting your idea. Please can you provide some content in the description about how you see this idea being implemented.