Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Showing 161

IS800:2007 result from multiple design blocks

Currently, if there are multiple design blocks present in a STAAD model, in the post-processing utilization table, design ratio from the last design block is reported. It is very common to define multiple design blocks with different set of parame...
Surojit Ghosh over 1 year ago in  1 Future consideration

Cold formed Member design to EN 1993-1-3

Many STAAD users in Singapore and Malaysia have requested to implement the cold formed member design to EN 1993-1-3. We have lost some prospects to competitors because of the absence of this code in STAAD.Pro. This may be a feature that is request...
Madhan Elumalai over 1 year ago in  3 Future consideration

Physical Modeler - Allow multiple wind load definitions to be combined into one primary load case

Because you must create multiple wind definitions for wind along a single direction (i.e. windward, leeward, sidewall) it would be helpful to have the ability to combine these in a single load case. Combining them in the load combos is cumbersome....
Ryan Freund over 1 year ago in  1 Future consideration

Multiple mass models/ seismic analyses for design

Many codes, particularly IS 1893 part-2 and IS 3370 part-2, the RCC elevated/underground water retaining structure should be analyse and design in "TANK ENPTY" and "TANK FULL" both of the conditions, but staad pro seismic definition whether it is ...
Sahil Shaikh over 1 year ago in  2 Future consideration

Add a command to modify tension Flange net area for AISC 360 F13

There is the command NSF that modifies the net area of the whole member, but there isn't a command to modify the net area of the tension flange only to apply it to section F13 in AISC.
Dallin STRONG over 1 year ago in  2 Future consideration

Auto wind load generation for roof/purlins..

Frequently used for design of all steel structure with shed/roof CONCERN CODE(ALL) especially IS 875 part 3: 1-Sir, staad CE has support the auto wind load as for clad/unclad buildings, this wind load is applied on the surfaces/periphery of buildi...
Sahil Shaikh over 1 year ago in  3 Future consideration

Design Lacing and battening column to IS800:2007

Widely used in industry
Sahil Shaikh over 1 year ago in  4 Future consideration

Auto reducible live load in Staad for IS 456 part 2

No description provided
Sahil Shaikh over 1 year ago in  3 Future consideration

Add code checks for AISC 370

There is a new code for Stainless Steel that has been published by AISC. It would be nice to incorporate the code checks for AISC 370 for materials that have been selected as stainless steel.
Dallin STRONG over 1 year ago in  10 Future consideration

Add latest US Aluminum Design Code

STAAD.Pro has offered aluminum design and ASD code checking for many years based on the 1994 Aluminum Design Manual. Since that publication was issued 26 years ago, there have been five subsequent versions released in 2000, 2005, 2010, 2015, and 2...
Steve Haymore over 1 year ago in  5 Future consideration