Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Showing 418

Add angle section to ram connnection so that the Lattice structure can be calculated

Add angle section to ram connnection so that the column base node of Lattice structure can be calculated
Guest 11 months ago in  1 Needs review

Design Lacing and battening column to IS800:2007

Widely used in industry
Sahil Shaikh almost 3 years ago in  5 Future consideration

Postprocessing display of multiple design blocks for AIJ codes

Currently, it is possible to display results for multiple design blocks with AISC360-16 results only. This feature is also required for AIJ2005 and 2002. In AIJ codes, load cases are classified into parmanent loads, temporary loads and loads for...
佐野 秀昭 Hideaki Sano almost 2 years ago in  1 Future consideration

Report for pictures of the structure.

Staad should have one option which helps to create a report of node labels ( tier/levewise) for whole structure. Also a report of beam labels ( tier / levelwise) for the whole structure. Also report of section property ( tier/levelwise) for whole ...
Guest almost 3 years ago in  1 Will not implement

Section properties edit to remember previous selection

When you open a Section from the Properties panel by double-click, you are prompted to the same Table, including section type as the one you double-clicked. That is OK. But the table is just opened regardless of what section size or configuration ...
Guest almost 2 years ago in  1 Already exists

Pipelink Improvement

The pipelink transfer of loads from AutoPIPE to STAAD is currently very limited for guide-type supports and other multi-direction supports. A guide support will have vertical loads as well as lateral loads. Depending on the direction of the latera...
Michael Wood almost 2 years ago in  5 Needs review

OpenSTAAD function to turn on members stress ratio.

To streamline the design process using the OpenSTAAD function, we aim to automate the visualization of member stress ratios for each analysis. Currently, when employing the "objOpenSTAAD.View.SetModeSectionPage 1, 6, 19" function, the stress ratio...
Kanagarasu Kandasamy almost 2 years ago in  2 Future consideration

Show design ratio for concrete members as is shown for steel members

When designing concrete members in Staad.Pro, detailed design information can be seen in batch mode using TRACK command. One useful detail is the design ratio Pu/Pn. If that value can be shown the same way is shown for steel design it can speed up...
Guest almost 2 years ago in  1 Future consideration

Use Center of the Structure as rotation Center

The Orientation Settings window provides the option "Use the center of the structure as the rotation center". However, when i perform the "Display Whole Structure" function, the rotation center is reset to 0,0,0. This happens when the Orientation ...
Guest about 1 year ago in  0 Needs review

display of design results for different design parameters

It is understood that only for AISC 360 design checks, it is feasible to view the design results for different design parameters & maximum case, while the same is not allowed for other design codes without going in to output file. Appreciate t...
Sreekanth Nuthanapati about 2 years ago in  5 Future consideration