Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Showing 64

I sections with side plates

It is suggested to add I sections with side plates table under specifications user table manager tabs. Offshore brownfiled modificaitons work would involve adding side plates to existing I sections to increase its capacity.
Guest 12 months ago in  1 Needs review

Wind loading on cylindrical structures as per IS 1875 part 3

Provide a method to create wind loading on Cylindrical Structures as per Wind Pressure coefficients in clause 7.3.3.7 using Table 19 of IS 875 Part-3 2015
Guest about 1 year ago in  4 Needs review

Automatic combinations should only include notional loads in the direction of the main lateral load

Hello, There’s no point in applying the notional load against other lateral loads. In STAAD, it’s possible that the Load Combination where automatically generated so the notional loads are generated for all directions even if they countermeasure t...
Jacques ARNOLD about 1 year ago in  2 Needs review

property reduction factor for plates

dear staad pro team,i think more important things for shar wall system building for high rise building is property modifires for wall,it is misssing in staad pro i dont know why?all softwares have this important feature why is missing in staad?
Guest about 1 year ago in  6 Needs review

Reuse the water tank module to form a retaining wall module in SPPM

Are there any plans to use the Water Tank module in Structure Wizard in the Physical Modeler to create a retaining wall module? It seems like this could be developed easily from the water tank module.
Richard Tully almost 2 years ago in  1 Needs review

ASCE 7-22 and AISC 360-22

Please add AISC 360-22 and ASCE 7-22 in STAAD PRo. Codes already 2-years old.
Guest 24 days ago in  0 Needs review

Improve Curved Member Rendering and Analysis in STAAD.Pro

Executive Summary: This proposal outlines the need for enhancements to the rendering and analysis capabilities of curved members within the STAAD.Pro software. While curved members are essential for accurate modeling in various engineering applica...
Guest about 1 month ago in  0 Needs review

Beam utilization listing with drop down box

The "actual ratio" button in postprocessing mode is not working for a lot of users in Subsea7. This button is supposed to re-arrange beam utilizations from default beam number order, to utilization ascending order, and is very helpful. The problem...
Guest 3 months ago in  2 Needs review

Inclusion of SS EN 1998-1 Seismic Action & Accidental Torsion

Application of seismic action (including accidental torsion) for structure in Singapore using EN 1998-1 is cumbersome. Request to include this code in future development.
Guest 4 months ago in  2 Needs review

ASEC7 vertical structural irregularities check

The STAAD.Pro now can not check the the vertical structural irregularities 5a/5b in the ASCE 7 table 12.3-2 by ant command stream, but as the code demand, the designer need check this irregularities, it is very difficult and cost time for designer...
Guest 5 months ago in  1 Needs review