Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

STAAD.Pro

Showing 197

Auto Wind load for roofing

Implement a method to generate loading on roof structures as per the IS 875 part 3 wind load code using the Cpe method using the values in Table 8 / 9
Sahil Shaikh about 3 years ago in  6 Future consideration

State the code basis for utilization ratio tables in reports

In STAAD 2023, if a report is created and the Utilization Ratio table is included, a critical Clause is listed for each member. However, there is no indication in/above the table of which code, or code version, that the Clause pertains to. Please ...
Steve Haymore about 1 year ago in  2 Future consideration

EN1993-1-1 Eurocode 3 2005

STAAD.Pro- software is using EN1993-1-1 Eurocode 3 2005, - this is not the latest version of this design code. How do we go about updating this in STAAD-Pro ? We need to be using the latest design code for compliance with our EN1090 fabrication wo...
Guest over 1 year ago in  1 Future consideration

Make Staad Multi Processor (Multi-Threaded)

This would cut down the analysis time required by STAAD significantly. If it is too much work to change the solver code to benefit from multi-threads, can at least each basic load or each load combination be run at a different thread? There's no r...
Rafael Salgado almost 3 years ago in  1 Future consideration

Auto wind load generation for roof/purlins..

Frequently used for design of all steel structure with shed/roof CONCERN CODE(ALL) especially IS 875 part 3: 1-Sir, staad CE has support the auto wind load as for clad/unclad buildings, this wind load is applied on the surfaces/periphery of buildi...
Sahil Shaikh about 3 years ago in  4 Future consideration

Calculate section properties when adding new shape to database

Two things here:Have the ability for STAAD (in the physical modeler) to calculate the section properties when entering a new shape into an existing database. For example, I'm adding a new hat channel into the AISI cold formed Profiles database. In...
Ryan Freund about 3 years ago in  4 Future consideration

In wind load generator, please incorporate wind load in other directions such as X & Z. Also, wind load on roof truss & corners needs to be incorporated.

There is no way to add wind load in other direction in case of unclad building. For example : - staad taking load case only in one direction i.e. +X, whenever I try to add another case in z direction, previous case gets deleted automatically. So, ...
Shubhankar Chatterjee about 2 years ago in  3 Future consideration

Direct Analysis Method with Tension-Only members

Just as the title. To be able to analyze a structure with Tension-Only members using the Direct Analysis Method.
Saul Cuen over 2 years ago in  1 Future consideration

Moving Loads Acting in Horizontal Directions

Provide the ability to have horizontal moving loads in addition to the vertical loads. For example, ASCE 7 requires cranes to be designed for vertical loads and horizontal loads. It would be great if STAAD had the ability to have both the vertical...
Jeremy Jacobs over 2 years ago in  3 Future consideration

Built-up tapered section name

All tapered section name shows as a tapered . its very useful if staad pro show the tapered section show the section in the display- Tapered I- 300x6+200x8+150x8 if its uniform web depth Tapered I- (300-750)x6+200x8+150x8 if its tapered web depth ...
Guest about 1 year ago in  2 Future consideration