Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

STAAD.Pro

Showing 363 of 363

Introduce "Dynamic pictures" for quick reports update

Hello, Could you introduce "Dynamic Pictures" in STAAD? Engineers spend a good amount of time in generating clearly annotated and detailed reports within all project's lifecycle. In a competitive environment, hitting timelines is paramount. A dyna...
Ola Joda 8 months ago in  1 Future consideration

Eurocode Wind Load Automatic Generation

Please add the ability to automatically generate wind loading to eurocodes.
Guest over 1 year ago in  1 Future consideration

ANGLE STAR AISC LRFD CODE CHECK

No description provided
Guest 8 months ago in  3 Needs review

Improve beam/node selection for reporting loads

Add some kind of functionality to categorize "connection types" to simplify reporting of loads. While there is functionality to group members and to group nodes, there is no way to overlap them. When I want the connection loads for certain members...
Michael Wood 9 months ago in  6 Needs review

Postprocessing display of multiple design blocks for AIJ codes

Currently, it is possible to display results for multiple design blocks with AISC360-16 results only. This feature is also required for AIJ2005 and 2002. In AIJ codes, load cases are classified into parmanent loads, temporary loads and loads for...
佐野 秀昭 Hideaki Sano over 1 year ago in  1 Future consideration

Section properties edit to remember previous selection

When you open a Section from the Properties panel by double-click, you are prompted to the same Table, including section type as the one you double-clicked. That is OK. But the table is just opened regardless of what section size or configuration ...
Guest over 1 year ago in  1 Already exists

Pipelink Improvement

The pipelink transfer of loads from AutoPIPE to STAAD is currently very limited for guide-type supports and other multi-direction supports. A guide support will have vertical loads as well as lateral loads. Depending on the direction of the latera...
Michael Wood over 1 year ago in  5 Needs review

Include a Quick button to "Un-assign" or "remove assigned" Loads from Member/ Elements

Hello Development Team, Could you consider adding a quick "button" to execute "un-assign" or " remove load " command from both plate elements & line members ? (Please refer to the attached picture). This tool would work as a quick "reverse ope...
Ola Joda 9 months ago in  1 Already exists

OpenSTAAD function to turn on members stress ratio.

To streamline the design process using the OpenSTAAD function, we aim to automate the visualization of member stress ratios for each analysis. Currently, when employing the "objOpenSTAAD.View.SetModeSectionPage 1, 6, 19" function, the stress ratio...
Kanagarasu Kandasamy over 1 year ago in  2 Future consideration

Improve GUI and STAAD Editor operability

Please allow user to remove multilinear springs in GUI rather than going into the editor to remove 1 or 2 lines of text.
Guest 9 months ago in  1 Future consideration