Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Showing 95

Inclusion of SS EN 1998-1 Seismic Action & Accidental Torsion

Application of seismic action (including accidental torsion) for structure in Singapore using EN 1998-1 is cumbersome. Request to include this code in future development.
Guest 7 months ago in  2 Needs review

Auto load combination for IS 802 part 4

It will be better is auto load combination for following IS codes, IS 802 Part 1/Sec1 2015 - Clause 13 - For Transmission tower Design IS 802 Part 4 2023 - Clause 13 - For latticed switchyard structure Design As of now only design code of IS 802 i...
Pandiaraja Veluchamy 3 months ago in  0 Needs review

Beam Orientation arrows - scale/size

In STAAD.Pro Advanced 2024, please add tool to adjust the scale (size) of the "Beam Orientation" arrows. it is impossible to distinguish from one member to another with the arrows so large.... this was an isolated view of a portion of a much large...
Jim Rudelich 3 months ago in  0 Needs review

Warning based on superceded (old) code appears in Seismic analysis using IS 1893 pt 1.

STAAD Pro CONNECT Edition shows a warning based on IS 1893 part 1:2002, when the latest code available currently under use is IS 1893 part 1:2016. Kindly clarify why should warnings based on old codes appear when the user has specifically selected...
ABHISHEK Ramesh about 2 months ago in  0 Needs review

Open STAAD function for changing a existing tapper property

Please add one open STAAD function in which we can edit existing tapper property it will same much time
Arjun Prabhu Masure 5 months ago in  1 Needs review

Steel Check Code for all code, please make it uniform format

ANL file for steel code has changed format can you revert back again or atleast put to option on Track command to retain original format.
Guest about 2 months ago in  0 Needs review

Add steel fireproofing specification to STAAD.pro Physical Modeler.

Currently, the only way to use STAAD.pro fireproofing specification is thru the Analytical Modeler. If you have a physical model, you have to break the connection and then edit the Input file to remove the "DO NOT EDIT" restrictions so that you ca...
Guest about 2 months ago in  0 Needs review

Option/Command required to view failed RCC members.

I believe there is no option or command to directly view RC members that have failed, similar to that of "Utility" option available for checking failure of steel members. Failure of RC members must be manually checked from the "Analysis Output" op...
ABHISHEK Ramesh about 2 months ago in  0 Needs review

Automatically generate Image Reports

Please add an option to generate an image report for every load case. The image report are showing how the forces are affecting the structure (see attached screenshots). Currently it is only possible to manually create a screenshot for each load c...
Michael Kikinzon over 2 years ago in  1 Needs review

Convert beams to shells for FEA

It would be great to be able to mesh a STAAD stick model using the assigned profiles (i.e. having the software replace the beam with a set of plates to match the flange/web sizes and thicknesses) in order to do some high level finite element analy...
Guest 5 months ago in  3 Needs review