Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Insert node in members having built-up I-Section property.

Hi, When inserting a node into a beam having a tapered I-section property, the software automatically generates the properties for the new section and places it at the end of the property section. This poses significant challenges during the optim...
Kanagarasu Kandasamy almost 3 years ago in  3 Future consideration

CANADA/NRC seismic code 2023

Presently Staad pro is using CANADA/NRC seismic code 2010, but available code is 20213 , kindly update your Staad soft ware accordingly, to perform our Canadian client asap
Guest 11 months ago in  0 Needs review

Turkish Building Earthquake Code 2018 for steel structures

Betonarme binaların projelendirmesi ile birlikte çelik binaların projelendirilmesinde de kendi ülke standart ve kurallarını kullanmak, mühendislerimiz için kolaylık ve rahatlık sağlayacak, programlarınızın ülkemiz içerisinde kullanımının yaygınlaş...
Yahya Karadede almost 2 years ago in  3 Needs review

Untie the Section Name in the Properties window from the Base Unit settings

The proposed enhacement would allow the units that are being used in the model to appear correctly and complete in the Section Name window, and also in the reports because, for example, being tied as they are now only allows units to be presented ...
Alberto Prieto Noyola 11 months ago in  0 Needs review

The name of the load can be modified

When there are many types of load definitions, it is difficult to distinguish which one each load is. If you can customize the name, it will be easier to distinguish and verify
Guest almost 2 years ago in  5 Already exists

Add fire calculation in staad.pro

according to GB 51249-2017, steel structure needs to do the fire calculation and corresponding design. There are more and more security reviews about fire calculation, therefore it's necessary to add these content in staad.pro.
Guest almost 2 years ago in  1 Future consideration

JIS/TIS c-light lip section database for coldform steel design

Too many requirement for design the JIS/TIS c-light lip section as cold formed steel using STAAD. So, is it possible to have an JIS/TIS c-light lip section properties included in the database. If there are these section database in STAAD, it's can...
Support REI almost 3 years ago in  1 Future consideration

There sholud be a Way to Create a Physical Model from a working Analytical Model!

I know there is a way to use Copy/Paste Nodes, Members, Properties, Materials, etc.Not Talking about the hard way of doing things- which involves trial and error and a lot of clean up. Since the new recommended Workflow is promoting a Physical Mod...
Guest almost 3 years ago in  2 Future consideration

Update Canada steel structure design standard to CSA S16 :2024

No description provided
Guest 12 months ago in  0 Needs review

Calculation of Stability index Q as per annex E of IS456

To determine whether a column is a no sway or a sway column, stability index Q may be computed as given in annex-e of IS456. It's a very time consuming and cumbersome calculation while we are freezing the column sizes. if Q is directly calculated ...
Guest almost 2 years ago in  4 Future consideration