Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Showing 46

Ciudad de Mexico NTC code 2023

To update/include the specifications for mexican regulation for Ciudad de Mexico to the latest version 2023 which include loads specifications, seismic, wind, or at least the steel and concrete.
Guest 1 day ago in  0 Needs review

AISC 360-22 availabilty in STAAD.Pro

As title, to update design code for AISC 360 to version 2022.
Guest 1 day ago in  0 Needs review

base pressure contour is not available for the envelope of the loads

Base pressure contour for raft footing is available for the envelop of the loads in Space Gass but not in STAAD. It is important to have this feature be implemented in STAAD too to facilitate the raft footing design based on allowable bearing pres...
Guest 17 days ago in  0 Needs review

Staad Foundation Advance V9

For pile cap design it will be helpful to include summary of pile forces for all the piles in the calculation report. Current version only provides a summary table of maximum pile reaction for service load cases but not all the piles. If I have to...
Guest 18 days ago in  0 Needs review

Add angle section to ram connnection so that the Lattice structure can be calculated

Add angle section to ram connnection so that the column base node of Lattice structure can be calculated
Guest about 1 month ago in  1 Needs review

The STAAD.Pro model import to SACS

Now we can calculate the upstructure in STAAD.Pro for ocean engineer; But the pile will be designed in SACS for sea ice load and wave load. when the model is imported to SACS, the load will loss and need to apply load again in SACS. The workload i...
Guest about 2 months ago in  1 Needs review

Turkish Building Earthquake Code 2018 for steel structures

Betonarme binaların projelendirmesi ile birlikte çelik binaların projelendirilmesinde de kendi ülke standart ve kurallarını kullanmak, mühendislerimiz için kolaylık ve rahatlık sağlayacak, programlarınızın ülkemiz içerisinde kullanımının yaygınlaş...
Yahya Karadede about 2 months ago in  3 Needs review

Use Center of the Structure as rotation Center

The Orientation Settings window provides the option "Use the center of the structure as the rotation center". However, when i perform the "Display Whole Structure" function, the rotation center is reset to 0,0,0. This happens when the Orientation ...
Guest 2 months ago in  0 Needs review

ADD the slenderness ratio to the normalized ratio

If the slenderness ratio meets the requirements, but its normalized ratio is not shown in the utilization table, can the slenderness ratio be added to the utilization table, which will help the designer to understand the condition of the member.
Guest 3 months ago in  1 Needs review

ANGLE STAR AISC LRFD CODE CHECK

No description provided
Guest 3 months ago in  3 Needs review