Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.
You have 3 options for providing feedback:
Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.
Comment on an existing Idea. We want to hear your unique point of view.
Add a new Idea. If no existing Idea describes what you would like, add a new one!
When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!
Thank you for posting this idea. I believe you are suggesting that when a response spectrum has been defined and storeys are indicated using the FLOOR DIAPHRAGM, then by adding an additional command such as PRINT STOEY SHEAR, the total applied shear force applied at that level form all model shapes is reported in each of the two lateral directions. When considering non dynamic cases including wind and static seismic cases, then the total lateral shear is reported for that case. Hence if you only want this reported for a limited number of load cases, then this would be filtered based on the current LOAD LIST definition. Does that perhaps better summarise your idea? If not please can you explain further.