Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Showing 182

Built-up tapered section name

All tapered section name shows as a tapered . its very useful if staad pro show the tapered section show the section in the display- Tapered I- 300x6+200x8+150x8 if its uniform web depth Tapered I- (300-750)x6+200x8+150x8 if its tapered web depth ...
Guest 2 months ago in  1 Future consideration

5% accidental eccentricity as per Eurocode 1998:2004, using response spectra method

The accidental eccentricity in staad pro. as per Eurocode 1998:2004, while analyzing the structure for seismic loads using response spectra method.
Guest 3 months ago in  1 Future consideration

State the code basis for utilization ratio tables in reports

In STAAD 2023, if a report is created and the Utilization Ratio table is included, a critical Clause is listed for each member. However, there is no indication in/above the table of which code, or code version, that the Clause pertains to. Please ...
Steve Haymore 3 months ago in  2 Future consideration

Ciudad de Mexico NTC code 2023

To update/include the specifications for mexican regulation for Ciudad de Mexico to the latest version 2023 which include loads specifications, seismic, wind, or at least the steel and concrete.
Guest 4 months ago in  1 Future consideration

Allow Z up for RAM connection design

RAM connection design cannot be used in a model with SET Z UP specified. This is a crippling limitation of the software.
Michael Wood 5 months ago in  2 Future consideration

Turkish Building Earthquake Code 2018 and TS 500

Türkiye de yaşayan mühendislerin programlarınızı kendi ülke standart ve kurallarına göre daha rahat kullanabilmeleri ve bunun paralelinde programlarınızın kullanım oranlarının artması doğrultusunda eklenmesi yaralı olacaktır.
Yahya Karadede 5 months ago in  4 Future consideration

Add fire calculation in staad.pro

according to GB 51249-2017, steel structure needs to do the fire calculation and corresponding design. There are more and more security reviews about fire calculation, therefore it's necessary to add these content in staad.pro.
Guest 6 months ago in  1 Future consideration

Modify design parameter "PROFILE"

Design Parameter "PROFILE" seems to check only first 3 characters. If I understand correctly, STAAD already selects the lightest section only for the same kind of section as the current one, and the limit on the height can be set by variables DMAX...
Guest 6 months ago in  3 Future consideration

Calculation of Stability index Q as per annex E of IS456

To determine whether a column is a no sway or a sway column, stability index Q may be computed as given in annex-e of IS456. It's a very time consuming and cumbersome calculation while we are freezing the column sizes. if Q is directly calculated ...
Guest 6 months ago in  4 Future consideration

Introduce "Dynamic pictures" for quick reports update

Hello, Could you introduce "Dynamic Pictures" in STAAD? Engineers spend a good amount of time in generating clearly annotated and detailed reports within all project's lifecycle. In a competitive environment, hitting timelines is paramount. A dyna...
Ola Joda 7 months ago in  1 Future consideration