Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

Status Needs review
Created by Guest
Created on Jun 15, 2023

Direct Analysis Method. Reduction stiffness for Strength and nominal stiffness for Service

According to the code and standard practice, stiffness reduction for DAM applies for Required Strength analysis, but for Design Strength calculation and for Service check, nominal stiffness is to be used.

To be able to indicate Staad which combinations are Service combinations so, for those, use nominal stiffness.

  • Admin
    Carlos Aguera
    Reply
    |
    Jun 19, 2023

    Thank you for posting this idea, but I am not clear what your proposed idea is? If you are suggesting that it should be possible to perform DA on some load cases and regular analysis on others, then that is already possible with STAAD.Pro.

    2 replies