Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

STAAD.Pro

Showing 183

Add the ability to add wind loads to plate elements

It would be nice to be able to apply wind loads on plate elements. Especially given that there is a wind load definition specifically for tanks, but no way to model that tank other than plate elements. The alternatives are a cumbersome to implemen...
Dallin STRONG about 3 years ago in  2 Future consideration

Add live load reduction factor as design parameter

There is currently no efficient way to consider the live load reduction factor in STAAD.Pro. It would be fantastic to add a parameter to the design section (e.g., under CSA S16-19 or AISC 360-16) to consider a live load reduction on an element by ...
Guest over 1 year ago in  4 Future consideration

Multiple design parameters results in post processing window for Indian code IS 800-2007 is requested.

This will reduce the tedious process of turning on and off each design parameter from editor file and then running the full input file again multiple times. If this can be implemented for AISC-360 then it shall be implemented for other codes also.
Guest 11 months ago in  1 Future consideration

MEMBER FORCES - GLOBAL Coordinate System

STAAD cannot report Beam Results in the Global Coordinate Systems in the UI Results Table. However, it is capable of printing Member Forces using the Global Coordinate System to the Analysis Report. This hinders downstream processes that require t...
Sujaan Ahamed Fareed almost 2 years ago in  4 Future consideration

Staad Pro does not include Seismic load NBCC 2015

Dear All, I highly recommend to include calculation of seismic load using NBCC 2015. I see it as a big gap in Staad Pro not to include Seismic loading using NBCC 2015 Thanks a lot
Guest about 4 years ago in  1 Future consideration

Add load to the node/beam/element group using OpenSTAAD

Hi, I have an OpenSTAAD program that generates groups and that applies loads to the elements/beams/nodes in those groups. However I'd like to apply the load to the group directly using openSTAAD as you can in the STAAD Command File? What I want to...
Tom Pallister 11 months ago in  1 Future consideration

Ciudad de Mexico NTC code 2023

To update/include the specifications for mexican regulation for Ciudad de Mexico to the latest version 2023 which include loads specifications, seismic, wind, or at least the steel and concrete.
Guest 6 months ago in  1 Future consideration

Provide wind generation on Fireproof Members

STAAD does not consider the additional width of the fireproofed members; producing underestimated wind generated loads for open structures like piperacks. Please include this feature as this would make several of my colleagues happy.
Guest about 5 years ago in  5 Future consideration

Add NZS 1170.5 code to Seismic Codes in STAAD

STAAD does not have NZS 1170.5 in its Seismic Codes. Users in ANZ uses custom spectrum and factored it up to match the base shear. Adding this code will help the users in ANZ work directly with the NZ code and thus speed up their productivity. Use...
Rudra Lahiri over 2 years ago in  1 Future consideration

Multiple mass models/ seismic analyses for design

Many codes, particularly IS 1893 part-2 and IS 3370 part-2, the RCC elevated/underground water retaining structure should be analyse and design in "TANK ENPTY" and "TANK FULL" both of the conditions, but staad pro seismic definition whether it is ...
Sahil Shaikh over 2 years ago in  2 Future consideration