Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Showing 43

RCDC not reading beams over slab tank

dear teams,please make corrects for software when you design water tank with slab including beams,RCDC not reading beams,plz correct it,thanks in advance
barham ibrahim almost 2 years ago in  1 Will not implement

Lacing and battening design of column

No description provided
Sahil Shaikh about 2 years ago in  2 Will not implement

Additional Selection Tools

It would be much helpful if additional tools to select entities like Nodes, Beams etc., in the polar coordinate system i.e., specifying the start and end radius (or diameter) and start and end angles. This helps a lot if we need to select the enti...
Srinivasa Rao Masanam about 1 month ago in  1 Will not implement

AI Assistant in Staad.Pro

The possibility of adding an 'AI Assistant' type tool, for example: "Alexa" or "Siri", which with natural language is able to interpret what the user asks for and execute the orders requested.
Guest about 1 month ago in  1 Will not implement

Highlight the beam when UDL selected

In load data page when you select any specific UDL or point load, then the UDL or point load associated beam and node shall be auto selected or highlighted. this will help to identify if load applied is at right location or not
Guest 7 months ago in  1 Will not implement

In Staad Pro 23.00.02.361, the size of the local coordinate system arrow cannot be enlarged or reduced simultaneously with the model. At present, the size of the local coordinate system arrow is too large. When there are many rod elements in the model, the local coordinate system almost covers the entire model, affecting other operations. Please provide improvement.

No description provided
Guest 7 months ago in  1 Will not implement

OSLoadUI::CreateLoadEnvelop function name is wrong

Please refer to the snapshot attached. The OSLoadUI::CreateLoadEnvelop function name is wrong. Please update in the next releases. Initially I could not find this function in the intellisense (by typing Create and left me wondering) and hence I am...
Srinivasa Rao Masanam 9 months ago in  1 Will not implement

GetUDLLoads command has probrem

I am testing Load.GetUDLLoads command. The contents of the returned D1Array will always be 0. For example, 1992 UNI 0.100 7.750 10.250, since 7.750 is not returned in D1Array,I can not check the range which the load is applied . D2Array truely ret...
takeshi nakahama 10 months ago in  1 Will not implement

Partial Moment Releases in Physical Modeller

Hi, please add the ability to add partial moment releases in the physical modeller. This seems like an important feature to me because if you have instability warnings it is often the case you need to provide a partial moment release to get rid of...
Guest 10 months ago in  2 Will not implement

Enable the basic design diagram for design results to be editable again by users

No description provided
Guest 11 months ago in  2 Will not implement