Skip to Main Content
STAAD.Pro Ideas Portal

Welcome to the STAAD.Pro Ideas portal. The purpose of this site is to post ideas for enhancements and new features. We value your feedback and our team regularly reviews your suggestions for consideration in future releases.

You have 3 options for providing feedback:

  1. Vote for an existing Idea. The popularity of an Idea helps us understand its importance to our users.

  2. Comment on an existing Idea. We want to hear your unique point of view.

  3. Add a new Idea. If no existing Idea describes what you would like, add a new one!

When you Vote, Comment, or Add an idea you will also be subscribed to that Idea and will receive status updates. Please note that we may merge or rename Ideas for clarity. Thank you for your support and feedback, it is always appreciated!

ADD A NEW IDEA

All ideas

Showing 10

Replace the Indian Section list based on the IS 808

As stated in case CS0627780, STAAD.Pro is currently using a section list based on the older version of the standard, IS 808:1989. However, this code has been superseded by the updated version, IS 808:2021. There are significant differences in sect...
RAHUL BRIJPUIYA 7 days ago in  4 Planned

Update feature for design of composite column and Beam to IS 11384:2022

Using two materials in beam or column sections enhances structural performance and allows for reduced member sizes. Composite sections exhibit lower deflections under lateral loads such as wind or seismic forces, resulting in reduced damage. Addit...
Guest about 2 months ago in  2 Planned

Inclusion of the newly released Indian Seismic Code IS 1893 (Part 1&5): 2025 in STAAD.Pro.

Since STAAD.Pro currently supports earlier IS 1893 versions, having the 2025 version integrated will be essential to ensure code-compliant analysis and safe design in India. The 2025 revision introduces major updates: A revised earthquake zone m...
Guest 2 months ago in  3 Planned

updated versions of IS 1893 Part - 1 & IS 1893 Part – 4 to be made available for STAAD.Pro Users in India

Updated versions of IS 1893 Part - 1 & IS 1893 Part – 4 to be made available for STAAD.Pro Users in India
Guest 2 months ago in  3 Planned

Correct the Seismic Zone Factor for Cuddalore, Tamilnadu, India in STAAD.Pro as per IS 1893 - Part 1 - 2016

Hello STAAD.Pro Team, While generating Seismic Definitions, the software automatically assigns the Zone Factor for Cuddalore, Tamilnadu, India as 0.16. This value is not aligned with local seismic requirements and also with IS 1893 - Part 1 - 2016...
Guest 5 months ago in  1 Planned

OpenSTAAD function for Circular Repeat

Is there a function to carry out the Circular Repeat (similar to DoTranslationalRepeat)?. If not, is it possible to introduce this function?
Srinivasa Rao Masanam 6 months ago in  3 Planned

For concrete design, DESIGN LOAD case should show to critical load case, regardless if minimum rebar is enough

When I model a concrete column in Staad.Pro, and perform the design, if the minimum rebar, lets say 1% is good enough for all load cases, the design load reported in the screen is the first load case. I understand because that rebar is OK for all ...
Saul Cuen 6 months ago in  1 Planned

Inclusion of Steel Take off list & Member take off list in User Report

I have noticed that currently there is no option to include Steel take off & Member take off list while generating Report. I request that this option be included in future upgrade.
Pawan Waghmare 8 months ago in  6 Planned

Implementation of IS18168 for steel design in STAAD Pro

No description provided
Vinayak Prabhavalkar 8 months ago in  1 Planned

Help and Users Manual of Japanese Language in Staad Pro

Let me request to provide the help and Users Manual of Japanese language in Staad pro. Currently It is not existing. So Japanese user cannot use Staad pro as the Calculation Note for Architectural application to Japanese government. If there is it...